home

See all integrations

ezyVet Knowledge Center

Get access to documentation, training, and other high-quality resources.

RocketPACS and diagnostic imaging requests

For staff to send diagnostic imaging requests to RocketPACS, a practice manager makes site diagnostic tests in ezyVet. Staff select an applicable site diagnostic test when they send a diagnostic request.

Note: Site diagnostic tests are necessary for RocketPACS because RocketPACS does not include supplied diagnostic tests.
The table that follows gives the settings and functions that are applicable to site diagnostic tests for RocketPACS diagnostic imaging requests. A practice manager uses the table when they make a site diagnostic test for RocketPACS.
Setting name Function
Code Use Code to enter a code for the type of diagnostic imaging.
Important: Do not enter a code that is more than 16 characters. If you enter more than 16 characters, ezyVet cannot send diagnostic imaging requests to RocketPACS.
Name Use Name to enter a name for the type of diagnostic imaging.
Supplier Use Supplier to select an applicable supplier contact record for the modality that you want to use. And make sure that you select the same supplier contact record of the RocketPACS integration that is configured for the applicable modality. For example:
  1. You want to make a site diagnostic test for an ultrasound modality of RocketPACS
  2. You find the RocketPACS integration that is configured for an ultrasound modality and do a check of the integration settings
  3. You record the name of the supplier contact record that the integration uses
  4. When you make a site diagnostic test for the ultrasound modality, use the Supplier box to select the same supplier contact record as (3)
Note: Make sure that only RocketPACS uses each supplier contact record that you make and use for RocketPACS modalities. Do not select supplier contact records that other integrations use.
Note: If ezyVet does not have a supplier contact record for a modality that you want to use with RocketPACS, make one.
Primary Billing Trigger Use Primary Billing Trigger to select an applicable diagnostic product. ezyVet uses the diagnostic product to automatically invoice the diagnostic imaging.
Form Do not use Form. The setting is not applicable to RocketPACS.
Default Diagnostic Interpretation Code If you want to use RocketPACS for diagnostic interpretations, use Default Diagnostic Interpretation Code to select an applicable diagnostic interpretation record. The record includes a diagnostic product that ezyVet uses as a billing trigger to automatically invoice the diagnostic interpretation.