home

See all integrations

ezyVet Knowledge Center

Get access to documentation, training, and other high-quality resources.

Configure a custom supplied diagnostic test for SediVue Dx urinalysis

Before staff can send an S-code diagnostic test for IDEXX Reference Laboratories, a practice manager must configure the test.

  1. Do the procedure given in Enable a diagnostic test for an IDEXX Reference Laboratories S-code
  2. Do the procedure given in Make a billing trigger product for SediVue Dx urinalysis
    Note: The billing trigger product is applicable to step 7 of this procedure.
To configure the test, do this procedure.
  1. Select Admin.
    The Admin tab
  2. In the settings list, select Clinical.
    The Clinical setting in the settings list
  3. Select Supplied Diagnostics.
    The Supplied Diagnostics setting
    ezyVet shows New Supplied Diagnostic screen.
  4. In the Code box, enter IVLS-SediVueUA(S)
  5. In the Name box, enter IDEXX VetLab Station UA Sedivue Anywhere
  6. In the Supplier box, select the supplier contact record of the applicable diagnostics integration.
  7. In the Primary Billing Trigger box, select the billing trigger product.
  8. In the Supplied Diagnostic Tests box, select SediVueUA - IDEXX VetLab Station UA Sedivue ($0.00)
  9. Select Save.
    The Save button
    ezyVet shows a confirmation message:

ezyVet has a configured test for SediVue Dx urinalysis that staff can select and use with a diagnostic request.